Brain wave models find clarity by splitting time from space
Treating electrode recordings and time steps as independent computational paths prevents artificial intelligence from relying on blurry averages when decoding electrical brain activity.

When a physician places a grid of sensors over a patient's scalp, the electrical pulses captured by each metal disc trace two distinct stories at once.12 One story unfolds across time, following the rhythmic oscillations and sudden spikes of voltage recorded by a single contact point. The other story unfolds across space, mapping how an electrical wave spreads across different regions of the cerebral cortex during the same fraction of a second. Standard machine learning models designed to process these signals have routinely flattened that distinction, allowing every measurement point across hours of recording to interact directly with every other point on the head.12 That approach assumes that any single millisecond at the frontal lobe might immediately correlate with an arbitrary millisecond at the back of the head, creating vast mathematical webs of potential connections.
A team of researchers at Mannas AI, an artificial intelligence research group, argues that this uniform treatment undermines how computers interpret brain activity.1 In a paper posted to the preprint server arXiv, researchers Mahir Jain, Parshva Runwal, Aditya Ray Mishra, Arvasu Kulkarni, Siddharth Panwar, and Sandeep Singh demonstrated that forcing an artificial neural network to treat the time axis and the electrode axis separately substantially improves its ability to read complex brain data.12 By breaking down the calculations into distinct temporal and spatial pathways, their architecture prevents the model from discovering deceptive mathematical shortcuts during unsupervised training.1 The work demonstrates that respecting the physical geometry of biological sensors produces more capable diagnostic tools.
Understanding the problem requires examining how electrical signals physically arise in the brain and reach scalp electrodes. First, a localized population of cortical neurons fires synchronously beneath the skull, generating an immediate fluctuation in electrical potential. Second, because brain tissue and bone act as volume conductors, that electrical fluctuation spreads outward nearly instantaneously, producing correlated voltage changes across multiple recording sensors positioned at different points on the head at that exact moment. Third, as the underlying neural circuit continues to cycle, the voltage at any individual electrode traces continuous rhythmic oscillations or sudden transient spikes over consecutive fractions of a second. A recording therefore possesses two natural, orthogonal axes: a spatial dimension across electrodes at one instant, and a temporal dimension across time for each individual electrode.
Why do standard transformer networks struggle with brain waves?
Standard transformer networks struggle with brain signals because their fundamental attention mechanism evaluates every token pair as equally relevant before learning, exposing low-signal biological data to thousands of spurious correlations.12 In modern machine learning, raw sensory inputs are split into small vectors called tokens.1 In an electroencephalogram, an instrument that records electrical activity on the scalp, each token represents a one-second segment captured from an individual electrode.1 When an algorithm scans an entire recording grid, dense self-attention permits long-range interactions without distinguishing whether two tokens share the same electrode or the same moment in time.1
This uniform arrangement becomes particularly vulnerable during masked autoencoding, an unsupervised training strategy where the model attempts to reconstruct missing or obscured patches of the sensory stream. Because dense global attention connects everything to everything, the paper reports that the model frequently learns to reconstruct a masked patch by computing a broad, fuzzy average across all electrodes and timestamps.1 This mathematical averaging works well for guessing missing numbers in the training data, but it erases the localized, sharp transitions that clinicians rely on to classify motor imagery or diagnose neurological conditions.1
Siddharth, a researcher at Mannas AI and co-author of the study, explained the underlying failure mode that emerges during unsupervised pretraining. In response to questions from Primary, Siddharth said that "in an EEG, the neighbouring electrodes record largely the same voltage through the skull, and a patch's slow drift is shared across the whole window." When an algorithm is asked to fill in missing patches under those physical conditions, "the cheapest way to fill a reconstruct patch is to average every visible patch on the scalp and copy the shared, slow component," Siddharth told Primary, noting that this simple trick "reproduces most of the reconstruction loss and none of the sharp, localized structure the model should actually learn."
Sandeep, a researcher at Mannas AI and co-author of the study, pointed out that this averaging pitfall frequently escapes notice in laboratory benchmarks. In vision research, models employ high masking ratios to prevent networks from simply interpolating nearby pixels, yet biological models often adopted those parameters without verifying if shortcuts persisted. Sandeep told Primary that "with a global path in the model, the reconstruction loss was identical to the model without it, so nothing in the training curve tells you anything is wrong." Sandeep observed that "on a low signal-to-noise signal like EEG, the averaging shortcut is invisible to the objective," concealing representation defects until models face downstream clinical tests.
How does the new architecture separate recording dimensions?
The new architecture, named the AXis-factorized Operator Network or AXON, separates recording dimensions by directing every token into two parallel computational branches: a temporal path that tracks a single electrode across time, and a spatial path that tracks all electrodes at a single instant.12 Instead of computing a single dense attention matrix across the entire grid of sensor measurements, AXON computes one set of attention weights within each channel group and another independent set across channels at the same timestamp.1 A small gating network then evaluates each token to compute a convex combination, outputting a weighted sum of the two pathways.12

The temporal path operates strictly within the boundaries of a single recording channel. For a token assigned to an individual electrode, the temporal neighborhood includes all tokens sharing that electrode identifier across the window.1 Channels do not interact through this branch, allowing the network to isolate rhythmic frequency oscillations, brief microvolt spikes, and baseline shifts without interference from distant sensor noise.1 Because electrophysiological events occur at contrasting durations, the authors constructed the temporal path with two parallel horizons: a short window covering five consecutive patches and a long window spanning the entire visible segment, with a learned parameter deciding how much each layer relies on short-term transients versus extended rhythms.1
Siddharth said that biological considerations guided the choice of that five-patch span. "Even along one electrode, a token should not have to attend to everything," Siddharth told Primary. "A motor-imagery response or a seizure onset develops over a few seconds, so a token that belongs to one of those events gains nothing from the rest of a ten-second window; it is mostly attending to noise." Siddharth added that the five-patch window, translating to roughly five seconds, corresponds to the operational duration of those events. While testing three windows of two, five, and all patches, the researchers found that additional intermediate horizons did not improve results because reconstruction loss failed to distinguish them.
The spatial path operates in an orthogonal direction, grouping all tokens recorded across different electrodes at the exact same time step.1 In this branch, attention operates across the scalp geometry at a static moment, evaluating spatial relationships between the front and back of the head. The spatial path receives no explicit physical three-dimensional coordinates during the attention calculation; spatial positions enter solely through positional encodings added to the input embeddings.1 Sandeep explained that encoding the geometry directly into the embeddings offers significant practical flexibility across varying clinical equipment. Sandeep told Primary that "a hard geometric constraint is a guess you make once and are stuck with, on one montage," while supplying positions through encodings "lets the same model run on any standard electrode layout."
Siddharth emphasized that removing direct all-to-all connectivity in a single layer does not isolate distant points permanently. "Factorization does not remove global reach; any two tokens still meet within two layers," Siddharth said in response to questions from Primary. "What it removes is the one-layer all-to-all average. The model has to build a masked patch out of what happens along one electrode over time and what happens across the scalp at one instant, and those are the two things that carry the physiology."
What did the experiments show across electroencephalogram benchmarks?
Testing across six standardized electroencephalogram benchmarks showed that the axis-factorized model achieved higher balanced accuracy than dense baselines under both linear probing and full fine-tuning regimes.12 The researchers pretrained their twenty-two-layer encoder on pooled recordings from the public TUH-EEG database, the I-CARE database, and proprietary internal data for 50 epochs with a batch size of 4,096. Recordings were standardized to 21 canonical electrode positions based on the international 10-20 system and segmented into 10-second windows containing 11 temporal patches per channel.1 During pretraining, the algorithm masked 55 percent of all tokens, forcing the network to infer the obscured brain data.1
To assemble the proprietary pretraining corpus, Mannas AI drew upon two large clinical and research cohorts. Siddharth told Primary that the internal pool included routine clinical neurophysiology covering 4,539 subjects and roughly 2,546 hours of resting-state, hyperventilation, and photic-stimulation tests from hospital departments, alongside a second group of multi-centre research recordings encompassing 1,050 subjects and approximately 435 hours. The team confirmed that neither collection shared subjects with the downstream evaluation tasks.
Across downstream evaluations covering motor imagery, cognitive workload, sleep staging, seizure detection, and dementia diagnosis, AXON achieved a mean balanced accuracy of 0.579 under linear probing, where the pretrained backbone is kept frozen while training a shallow classifier. That score represents a 2.9 percentage point gain over the standard dense baseline score of 0.550, and a 2.4 percentage point gain over a parameter-matched dense model named Dense-L, which achieved 0.555. Sandeep noted that evaluating frozen representations on unseen subjects provides a stringent benchmark for general-purpose foundation models. Sandeep told Primary that across six tasks on unfamiliar subjects, "the best of six published EEG foundation models we evaluated, REVE, reached 0.527," trailing AXON by over five percentage points.
Under full fine-tuning, where all model parameters are updated for downstream tasks, AXON achieved a mean balanced accuracy of 0.656, outpacing the standard dense baseline of 0.606 by 5.0 percentage points and the Dense-L model score of 0.633 by 2.3 percentage points. The performance gains proved especially pronounced on tasks requiring sharp temporal and spatial fidelity. In motor imagery classification evaluated on the motor dataset, linear probing balanced accuracy rose from 0.353 for the dense baseline to 0.455 for AXON, an increase of 10.2 percentage points. Sandeep highlighted that this margin carries practical weight for neural interfaces, explaining that a substantial jump on unseen users "shortens or removes calibration, and makes one model for a whole population realistic instead of one per user."
In dementia diagnosis evaluated on the adftd dataset under full fine-tuning, AXON recorded a balanced accuracy of 0.604 compared to 0.504 for the standard dense baseline, reflecting a 10.0 percentage point improvement. Ablation experiments verified that the benefits stemmed from structural factorization: forcing the model to make a hard choice between axes reduced performance, while removing either the temporal or spatial path entirely caused significant accuracy drops.1

Where does factorizing structured signals encounter practical limits?
The factorized framework is not an open-ended general solution for all sensory data, and its real-world gains depend heavily on whether physical boundaries naturally align with independent computational axes. The research describes evaluations conducted on curated research databases mapped to a fixed 21-electrode layout, rather than messy clinical environments where electrodes frequently disconnect, register muscle motion artifacts, or change positions between hospital visits.1 Although the authors excluded missing channels from tokenization and attention masks during testing, clinical electroencephalogram monitoring regularly deals with non-stationary sensor contact that can disrupt rigid axis-aligned assumptions.1
Siddharth clarified that the model is not fundamentally restricted to a single rigid montage. AXON accepts variable electrode counts because positional coordinates govern spatial orientation, and the authors evaluated the architecture across layouts with up to 64 electrodes. Siddharth told Primary that when channels were dropped at random during testing, AXON maintained an accuracy edge over dense baselines even when 94 percent of electrodes were removed. However, Siddharth cautioned that performance would degrade if sensor geometries deviated completely from standardized coordinate systems, leaving the spatial path without meaningful physical anchors.
Sandeep affirmed that factorized branches remain structurally resilient when electrodes detach during clinical monitoring. Because the temporal path processes each electrode independently, losing one sensor does not compromise calculations along surviving channels. Sandeep told Primary that while the architecture handled missing channels down to minimal contact counts, the research group has "not yet tested muscle artifact bursts or contacts that drop in and out within a window."
The value of factorization also varies across different cognitive tasks and signal modalities. On cognitive workload evaluation, a fixed-mixture baseline slightly outperformed AXON during full fine-tuning. Siddharth noted that diffuse neurological phenomena, including sustained cognitive strain or sleep staging, may sometimes benefit from broad global pooling because the signal is distributed across the entire brain rather than localized to a sharp event.
Furthermore, the exclusion of a global attention branch proved advantageous in electroencephalography but did not generalize uniformly across other signal types. When the authors tested a third dense branch in a variant called AXON-withGlobal on brain signals, its mean linear probing accuracy fell below that of factorized variants, with the first layer allocating a 0.724 gating weight to global averaging and weakening axis-specific features.1 Yet when the authors adapted the identical architecture to audio spectrograms using the AudioSet-2M corpus, the variant containing the dense global branch achieved the highest scores on three out of four evaluation metrics, scoring 14.29 percent mean average precision on AudioSet fine-tuning compared to 11.59 percent for the dense baseline.
Siddharth highlighted the physical differences between audio and electrophysiology that explain this divergence. In audio spectrograms, harmonic overtones, pitch sweeps, and acoustic onsets naturally create predictive relationships between different frequency bands across different time frames, meaning that off-axis connections carry real physical structure. In contrast, an unrelated electrode recorded several seconds later in an electroencephalogram typically captures volume-conducted noise and drift, making global averaging an easy route to masked reconstruction but a poor foundation for clinical classification.
The preprint also remains subject to formal peer review, having been posted directly to the arXiv repository in September 2026.12 While the empirical evaluations across six medical classification datasets are supported by standardized subject-disjoint splits, real-world clinical adoption will require validation across wider hospital cohorts, varying electrode montages, and real-time inference constraints. The current model serves as a proof of concept that inductive architectural biases matter when processing noisy biological signals.
What happens next for structured sensory computing?
The findings from Mannas AI demonstrate that machine learning models do not always benefit from unconstrained mathematical freedom. When deep neural networks are given unrestricted freedom to correlate any point in time with any point in space, they often learn superficial statistical shortcuts that collapse when asked to perform nuanced downstream diagnosis. By restricting attention along the natural physical dimensions of the recording instrument, engineers can preserve subtle biological waveforms that standard models smooth away.
The researchers note that this architectural bias extends naturally to other structured sensory systems. Beyond audio spectrograms, where frequency and time form natural orthogonal axes, similar factorized designs could apply to geophysical seismographs, hyperspectral cameras, or multielectrode neural implants.1 Sandeep noted that applying the framework to invasive brain implants would require adjusting temporal scales to accommodate higher frequency firing, though "the two-axis structure itself survives." For neuroscientists and biomedical engineers, aligning the geometry of neural networks with the physical reality of medical instruments marks an essential step toward reliable artificial intelligence in patient care.
The record
43 sentences trace to 2 sources and 2 contributors.
- 1 Adaptive Anisotropic Attention for Axis-Structured Signals Preprint · may not have been peer reviewed See the source
- 2 Adaptive Anisotropic Attention for Axis-Structured Signals | Cool Papers - Immersive Paper Discovery See the source
- 3 Contribution — Sandeep Singh 11 statements added to this article
- 4 Contribution — Siddharth Panwar 12 statements added to this article
Other consulted pages2 pages
arxiv.deeppaper.ai4 pages
- All Research Papers - Arxiv Search | Arxiv - DeepPaper
- Arxiv Paper Search Engine - Find AI Research Papers | Arxiv - DeepPaper
- REVE: A Foundation Model for EEG -- Adapting to Any Setup with Large-Scale Pretraining on 25,000 Subjects | Arxiv - DeepPaper
- AI Research Papers With Code - Arxiv Search | Arxiv - DeepPaper
huggingface.co2 pages
jawatech.github.io1 page
paperz.arrangedbits.com1 page
runguoli.com1 page
arxiv.org5 pages
- REVE: A Foundation Model for EEG Adapting to Any Setup with Large-Scale Pretraining on 25,000 Subjects
- ASSR-Net: Anisotropic Structure-Aware and Spectrally Recalibrated Network for Hyperspectral Image Fusion
- A Unified Resolution-Conditioned Framework for Orthogonal Line-Scanning Image Fusion
- Adaptive Anisotropic Attention for Axis-Structured Signals
- Adaptive Anisotropic Attention for Axis-Structured Signals
Article history
-
Published 24 Nov 2026, 15:33Assembled by the Primary desk from 2 sources · 2 contributors · 43 cited sentences
-
Sandeep Singh
- Go to the sentence: A team of researchers at Mannas AI, an artificial intelligence research group, argues that this uniform treatment undermines how computers interpret brain activity.
- Go to the sentence: This mathematical averaging works well for guessing missing numbers in the training data, but it erases the localized, sharp transitions that clinicians rely on to classify motor imagery or diagnose neurological conditions.
- Go to the sentence: Sandeep told Primary that "with a global path in the model, the reconstruction loss was identical to the model without it, so nothing in the training curve tells you anything is wrong."
- Go to the sentence: Sandeep observed that "on a low signal-to-noise signal like EEG, the averaging shortcut is invisible to the objective," concealing representation defects until models face downstream clinical tests.
- Go to the sentence: The spatial path receives no explicit physical three-dimensional coordinates during the attention calculation; spatial positions enter solely through positional encodings added to the input embeddings.
- Go to the sentence: Sandeep told Primary that "a hard geometric constraint is a guess you make once and are stuck with, on one montage," while supplying positions through encodings "lets the same model run on any standard electrode layout."
- Go to the sentence: Across downstream evaluations covering motor imagery, cognitive workload, sleep staging, seizure detection, and dementia diagnosis, AXON achieved a mean balanced accuracy of 0.579 under linear probing, where the pretrained backbone is kept frozen while training a shallow classifier.
- Go to the sentence: Sandeep told Primary that across six tasks on unfamiliar subjects, "the best of six published EEG foundation models we evaluated, REVE, reached 0.527," trailing AXON by over five percentage points.
- Go to the sentence: In motor imagery classification evaluated on the motor dataset, linear probing balanced accuracy rose from 0.353 for the dense baseline to 0.455 for AXON, an increase of 10.2 percentage points.
- Go to the sentence: Although the authors excluded missing channels from tokenization and attention masks during testing, clinical electroencephalogram monitoring regularly deals with non-stationary sensor contact that can disrupt rigid axis-aligned assumptions.
- Go to the sentence: Sandeep told Primary that while the architecture handled missing channels down to minimal contact counts, the research group has "not yet tested muscle artifact bursts or contacts that drop in and out within a window."
-
Siddharth Panwar
- Go to the sentence: By breaking down the calculations into distinct temporal and spatial pathways, their architecture prevents the model from discovering deceptive mathematical shortcuts during unsupervised training.
- Go to the sentence: In response to questions from Primary, Siddharth said that "in an EEG, the neighbouring electrodes record largely the same voltage through the skull, and a patch's slow drift is shared across the whole window."
- Go to the sentence: When an algorithm is asked to fill in missing patches under those physical conditions, "the cheapest way to fill a reconstruct patch is to average every visible patch on the scalp and copy the shared, slow component," Siddharth told Primary, noting that this simple trick "reproduces most of the reconstruction loss and none of the sharp, localized structure the model should actually learn."
- Go to the sentence: Because electrophysiological events occur at contrasting durations, the authors constructed the temporal path with two parallel horizons: a short window covering five consecutive patches and a long window spanning the entire visible segment, with a learned parameter deciding how much each layer relies on short-term transients versus extended rhythms.
- Go to the sentence: "Even along one electrode, a token should not have to attend to everything," Siddharth told Primary.
- Go to the sentence: "A motor-imagery response or a seizure onset develops over a few seconds, so a token that belongs to one of those events gains nothing from the rest of a ten-second window; it is mostly attending to noise."
- Go to the sentence: "Factorization does not remove global reach; any two tokens still meet within two layers," Siddharth said in response to questions from Primary.
- Go to the sentence: "What it removes is the one-layer all-to-all average. The model has to build a masked patch out of what happens along one electrode over time and what happens across the scalp at one instant, and those are the two things that carry the physiology."
- Go to the sentence: The researchers pretrained their twenty-two-layer encoder on pooled recordings from the public TUH-EEG database, the I-CARE database, and proprietary internal data for 50 epochs with a batch size of 4,096.
- Go to the sentence: Ablation experiments verified that the benefits stemmed from structural factorization: forcing the model to make a hard choice between axes reduced performance, while removing either the temporal or spatial path entirely caused significant accuracy drops.
- Go to the sentence: The research describes evaluations conducted on curated research databases mapped to a fixed 21-electrode layout, rather than messy clinical environments where electrodes frequently disconnect, register muscle motion artifacts, or change positions between hospital visits.
- Go to the sentence: When the authors tested a third dense branch in a variant called AXON-withGlobal on brain signals, its mean linear probing accuracy fell below that of factorized variants, with the first layer allocating a 0.724 gating weight to global averaging and weakening axis-specific features.