Heart monitors fall short of brain waves in sleep tracking
Consumer wearables tracking cardiac rhythms struggle to replicate clinical sleep staging, showing that brain wave recordings remain necessary for medical assessment.

How do clinicians track the stages of human rest?
During a normal night of rest, the human brain and body cycle through distinct biological states. Neural activity shifts through three progressively deeper phases of non-rapid eye movement rest, followed by rapid eye movement periods marked by vivid dreaming and temporary muscle paralysis. In specialized hospital laboratories, medical staff track these nightly cycles using polysomnography, an overnight diagnostic recording that captures brain waves, heart activity, eye movements, and breathing rhythms at the same time.1 The resulting multi-signal trace provides doctors with a comprehensive picture of how well a person rests, helping specialists diagnose sleep disorders and evaluate long-term risks for cardiovascular problems and cognitive decline.1
Every thirty seconds of an overnight recording forms a discrete window of time known as an epoch.1 Under clinical diagnostic rules established by the American Academy of Sleep Medicine, a trained human specialist reviews each epoch and assigns it to one of five formal categories: wakefulness, three stages of non-rapid eye movement rest labelled N1, N2, and N3, or rapid eye movement rest.1 A person drifting toward rest first enters the light N1 stage, gradually descends into the deeper, restorative slow-wave oscillations of N2 and N3, and periodically shifts into rapid eye movement episodes. Because bodily repair, memory storage, metabolic balance, and immune defenses depend on this sequential progression, medical researchers treat the timing and distribution of these stages as an indicator of general biological health.1
Laboratory polysomnography requires substantial financial resources and demands considerable effort from both patients and clinicians. Patients must spend the night in an unfamiliar clinical bedroom, sleeping while connected to dozens of adhesive sensors and electrical wires glued across their scalp, chest, face, and limbs.1 A clinical technician must then dedicate several hours to examining the continuous paper or digital traces, scoring hundreds of individual epochs by hand.1 Furthermore, even experienced medical specialists do not always agree on identical epoch boundaries or stage classifications when inspecting the exact same record, introducing human variation into clinical assessments.1
Automated software models offer a way to eliminate this human scoring bottleneck by processing a complete overnight diagnostic recording within seconds.1 Running digital algorithms over clinical recordings creates consistent and reproducible classifications, which is essential for expanding monitoring beyond occasional hospital visits. Researchers increasingly look to sleep traces as early warning indicators for complex conditions like dementia and broader metabolic disorders.1 However, gathering continuous diagnostic data across weeks or months in everyday homes requires hardware that people can tolerate outside a medical facility, where patients cannot be expected to sleep with rigid scalp sensors every night.
What happens when diagnostic channels are removed?
To determine how many physical recording channels automated software actually requires, lead author Hassan Mehdi and colleagues at the University of Turku, working with researchers from Turku University Hospital, University College Cork, University at Albany SUNY, Fudan University, and the University of Sydney, evaluated six artificial intelligence models across reduced signal configurations.1 Their investigation was posted to the arXiv preprint server in August 2026.1 The researchers sought to measure how much diagnostic classification performance declines when algorithms rely exclusively on consumer-friendly heart recordings rather than laboratory scalp electrodes.1
Before any software model can classify a stage of rest from a single physiological channel, an unbroken chain of biological events must register in the recording sensors. When brain cells synchronize their electrical firing during deep non-rapid eye movement rest, they generate large, rhythmic voltage fluctuations across the cerebral cortex that scalp electrodes readily detect. In contrast, cardiac sensors placed on the chest or wrist register only mechanical heart contractions, recording the electrical pulses that govern heartbeats. While autonomic nervous system signaling alters heart rate variability across different rest states, these cardiac changes represent indirect downstream consequences of brain activity, making stage boundaries harder to isolate from heart data alone.

To compare these physical modalities systematically, the authors evaluated six different computational architectures on recordings drawn from the Multi-Ethnic Study of Atherosclerosis dataset, which is distributed publicly by the National Sleep Research Resource.1 The team tested three distinct signal arrangements: a three-channel brain wave configuration, a single cardiac channel, and a combined four-channel setup merging brain waves and heart traces.1 The evaluated systems included BIOT and LaBraM, two foundation models pretrained specifically on medical electroencephalography data, alongside MOMENT, a general time-series foundation model pretrained on non-specialized public signals. The authors also tested an encoder trained from scratch using the SleepFM architecture, an implementation of the SensorLM vision transformer trained without pretraining, and YASA, a classical baseline pipeline that uses gradient-boosted decision trees over handcrafted features.1
Across the five models capable of processing heart data alone, switching from brain waves to an isolated cardiac channel produced an average performance decline of 0.3531 in macro F1, a balanced metric where 1.0 represents perfect agreement across all five stages.1 The smallest performance drop occurred in the general time-series model MOMENT, which lost 0.2798 macro F1 when shifting to cardiac data.1 The specialized biosignal model BIOT suffered the steepest decline, dropping by 0.4151 macro F1 when deprived of scalp channels.1 When evaluating brain waves alone, BIOT achieved the highest overall score with a macro F1 of 0.7237, followed by LaBraM at 0.6835 and the SleepFM encoder at 0.6582.1
Study co-author Muhammad told Primary that based on their findings, cardiac traces alone fail to supply the physiological detail needed for clinical sleep staging. “Based on our analysis, ECG signals alone did not clearly distinguish the sleep stages,” Muhammad said, noting that the team would caution against using isolated heart signals to flag sleep disorders, evaluate rapid eye movement rest, or support medical evaluations. Muhammad added that developers should avoid “selling heart-only devices as full sleep stage trackers, or reporting nightly deep-sleep and REM percentages as if they were measured,” even if simpler targets like detecting wakefulness prove more tractable.
The experimental results showed that combining heart recordings with brain wave sensors provided no meaningful performance gain for most of the evaluated models.1 While an isolated cardiac signal generated only a third of the raw data volume produced by three brain wave channels, that computational efficiency came at a steep cost in diagnostic precision.1 Brain wave traces carried the dominant share of the physiological information needed to separate the five stages of rest, showing that cardiac sensors alone miss critical neurological boundaries.1
Explaining this physiological divergence, Muhammad stated that manual scorers distinguish light N1 rest from rapid eye movement rest using eye movements and chin muscle tone rather than cardiac signals. “Heart rate changes with sleep state, but slowly,” Muhammad told Primary, pointing out that because cardiac variations follow broad bodily cycles rather than rapid neurological shifts, adding an electrocardiography channel to models lacking prior cardiac pretraining functioned more like noise and slightly degraded N1 classification.
How did the research team measure the diagnostic loss?
Hassan Mehdi and colleagues preserved the published structure of each evaluated foundation model, keeping network architectures intact while systematically altering only the input signal channels fed to them.1 For models requiring pretraining weights, the authors either preserved the published neural layers or retrained encoders from scratch using identical subject cohorts to prevent data contamination.1 For the SleepFM architecture, the team trained an encoder from scratch on their specific training split because the publicly released checkpoint had already seen recordings from the broader Multi-Ethnic Study of Atherosclerosis cohort during its initial training.1
The investigators extracted overnight diagnostic recordings from 350 participants within the Multi-Ethnic Study of Atherosclerosis, dividing the cohort into 270 individuals for training, 30 for validation tuning, and 50 held-out test subjects. Muhammad told Primary that the team selected these 350 recordings at random to test how foundation models cope with constrained resources before scaling up to the broader population. Raw European Data Format signals, originally recorded at 16-bit analog-to-digital converter resolution, were imported using the MNE-Python open-source library.1 The team applied a fourth-order Butterworth low-pass antialiasing filter with a 64-hertz cutoff frequency, resampled every channel to a uniform 128 hertz using linear interpolation, and normalized signal amplitudes with per-channel z-score calculations.1

At the standardized 128-hertz sampling rate, the raw channel data rate scaled directly with the number of attached sensors.1 A single cardiac channel generated 256 bytes per second, which equaled 33.3 percent of the 768 bytes per second required by the three-channel brain wave configuration. The combined four-channel arrangement demanded 1024 bytes per second, representing 133.3 percent of the brain wave baseline. Despite this additional bandwidth, adding cardiac data to brain wave inputs failed to enhance classification accuracy over scalp electrodes alone.1
To adapt each system to the classification task, the researchers matched each model to its native training protocol.1 For BIOT, the team fine-tuned an eighteen-channel checkpoint pretrained on the Sleep Heart Health Study and PREST datasets, using an AdamW optimizer with a learning rate of 0.0001, an effective batch size of 16, and an early-stopping patience of 20 epochs.1 Muhammad explained to Primary that BIOT dropped steeply when switched to heart data because its tokenization and attention layers were optimized for brain wave frequencies and scalp distributions, meaning the model encountered a waveform dominated by heartbeats that it was never structured to process.
For LaBraM, the team mapped recorded channels to standard 10-20 electrode positions, assigning the three brain wave derivations to scalp locations Fz, Oz, and C4, while directing the cardiac signal to location T9.1 Muhammad told Primary that because LaBraM requires designated cranial coordinates and lacks a dedicated cardiac slot, assigning the heart trace to T9 on the lower left periphery of the head served as an engineering workaround to prevent the model from misinterpreting heartbeats as dense frontal brain activity. For MOMENT, which contains 341 million parameters, the team froze the pre-existing transformer encoder and trained only a linear output layer across its concatenated representations.1
What do these performance limits mean for home wearables?
These findings come with specific limitations rooted in the study design and experimental scope.1 The research was conducted as a pilot-scale comparative evaluation restricted to 350 individuals drawn from a single public research cohort, chosen due to computational memory constraints encountered during testing.1 The paper reflects an experimental preprint posted to arXiv that has not yet undergone formal peer review.1 Furthermore, the researchers calculated raw transmission data rates from sample counts and bit depths rather than recording physical power consumption or wireless transmission metrics on consumer battery hardware.
The empirical gap between cardiac and brain measurements shows that wearable wristbands and chest straps cannot easily replicate clinical sleep staging. While consumer wearables capture heart rate patterns comfortably, translating those cardiac fluctuations into reliable medical classifications sacrifices substantial diagnostic certainty. For general wellness tracking, consumer devices provide accessible trend data, but clinical applications targeting neurological risk assessment still require the direct cortical signals provided by scalp electrodes.
The findings provide a benchmark for engineers designing low-power health monitors and edge-computing devices. Because adding cardiac channels to brain electrodes yielded no meaningful performance benefit, future clinical monitoring hardware can reduce computational overhead by omitting heart sensors when brain waves are already present. The investigation also demonstrates that foundation models pretrained on specialized brain wave corpora transfer their diagnostic capabilities effectively across distinct patient cohorts, outperforming general time-series models.1
Medical researchers will now need to test whether minimal single-channel scalp devices can bridge the gap between clinical fidelity and home convenience. Evaluating how channel reduction impacts downstream predictive tasks, such as forecasting dementia onset or cardiac mortality from long-term rest disruptions, remains an important next step. Until engineers develop non-intrusive scalp sensors that users can comfortably apply themselves, automated long-term sleep staging will continue to navigate the difficult compromise between clinical accuracy and home wearability.
The record
46 sentences trace to 1 source and 1 contributor.
- 1 Comparative Analysis of State-of-the-Art Foundation Models for Sleep Analysis Under Channel Reduction Preprint · may not have been peer reviewed See the source
- 2 Contribution — Muhammad Irfan 14 statements added to this article
Article history
-
Published 24 Nov 2026, 15:34Assembled by the Primary desk from 1 source · 1 contributor · 46 cited sentences
-
Muhammad Irfan
- Go to the sentence: Across the five models capable of processing heart data alone, switching from brain waves to an isolated cardiac channel produced an average performance decline of 0.3531 in macro F1, a balanced metric where 1.0 represents perfect agreement across all five stages.
- Go to the sentence: The specialized biosignal model BIOT suffered the steepest decline, dropping by 0.4151 macro F1 when deprived of scalp channels.
- Go to the sentence: Study co-author Muhammad told Primary that based on their findings, cardiac traces alone fail to supply the physiological detail needed for clinical sleep staging.
- Go to the sentence: “Based on our analysis, ECG signals alone did not clearly distinguish the sleep stages,” Muhammad said, noting that the team would caution against using isolated heart signals to flag sleep disorders, evaluate rapid eye movement rest, or support medical evaluations.
- Go to the sentence: Muhammad added that developers should avoid “selling heart-only devices as full sleep stage trackers, or reporting nightly deep-sleep and REM percentages as if they were measured,” even if simpler targets like detecting wakefulness prove more tractable.
- Go to the sentence: The experimental results showed that combining heart recordings with brain wave sensors provided no meaningful performance gain for most of the evaluated models.
- Go to the sentence: Brain wave traces carried the dominant share of the physiological information needed to separate the five stages of rest, showing that cardiac sensors alone miss critical neurological boundaries.
- Go to the sentence: Explaining this physiological divergence, Muhammad stated that manual scorers distinguish light N1 rest from rapid eye movement rest using eye movements and chin muscle tone rather than cardiac signals.
- Go to the sentence: “Heart rate changes with sleep state, but slowly,” Muhammad told Primary, pointing out that because cardiac variations follow broad bodily cycles rather than rapid neurological shifts, adding an electrocardiography channel to models lacking prior cardiac pretraining functioned more like noise and slightly degraded N1 classification.
- Go to the sentence: Muhammad told Primary that the team selected these 350 recordings at random to test how foundation models cope with constrained resources before scaling up to the broader population.
- Go to the sentence: Muhammad explained to Primary that BIOT dropped steeply when switched to heart data because its tokenization and attention layers were optimized for brain wave frequencies and scalp distributions, meaning the model encountered a waveform dominated by heartbeats that it was never structured to process.
- Go to the sentence: For LaBraM, the team mapped recorded channels to standard 10-20 electrode positions, assigning the three brain wave derivations to scalp locations Fz, Oz, and C4, while directing the cardiac signal to location T9.
- Go to the sentence: Muhammad told Primary that because LaBraM requires designated cranial coordinates and lacks a dedicated cardiac slot, assigning the heart trace to T9 on the lower left periphery of the head served as an engineering workaround to prevent the model from misinterpreting heartbeats as dense frontal brain activity.
- Go to the sentence: The research was conducted as a pilot-scale comparative evaluation restricted to 350 individuals drawn from a single public research cohort, chosen due to computational memory constraints encountered during testing.